JCL series low-pressure split unit

  • Details
    • Commodity name: JCL series low-pressure split unit

    System Model

     System Model

    JCL5KWH

    JCL10KWH

    Number of Batteries

     Number of Batteries

    1

    2

    Rated Energy

     Rated Energy

    5.22kwh

    10.44kwh

    Usable Energy

     Usable Energy

    4.70kwh

    9.40kwh

    Depth of Discharge / DOD

     Depth of Discharge / DOD

    90%

    90%

    Max Charge/Discharge Current

     Max Charge/Discharge Current

    50A/50A

    50A/50A

    Rated Voltage

     Rated Voltage

    51.2V

    51.2V

    Minimum Voltage

     Minimum Voltage

    44.8V

    44.8V

    Maximum Voltage

     Maximum Voltage

    58.4V

    58.4V

    Battery Type

     Battery Type

    LiFePO4

    LiFePO4

    Weight

     Weight

    66.8±0.1kg

    114.7±0.1kg

    Dimensions

     Dimensions

    598/200.5/746mm

    598/200.5/1149mm

    Operating Temperature

     Operating Temperature

    -20~55℃

    Relative Humidity

     Relative Humidity

    0%~100%

    Communication

     Communication

    CAN,RS485

    Installation Mode

     Installation Mode

    Floor-standing installation

    Protection Rating

     Protection Rating

    IP65

    Cooling Method

     Cooling Method

    Natural convection

    Scalability / Expandability

     Scalability / Expandability

    Up to two systems can operate in parallel

    Compatible Inverter

     Compatible Inverter

    GoodWe,Growatt,DEYE,CHINT,Kstar,KOYOE,etc

    Certification Standards

     Certification Standards

    IEC 62619,IEC 61000-6-1/2/3/4,UN38.3

    Remarks

    1)Optimal operating temperature range: 10-35℃, charging temperature range: 0~50℃, discharging temperature range: -20-55℃.
    2)Test conditions: Based on the production date, the charge and discharge current is 50A at 25℃ temperature and 90% depth of discharge.
    3)The weight of the battery module is subject to the actual product, with an allowable error of ±3%.
    4)The installation of the energy storage system is related to the quality assurance and safe and stable operation of the product. Please follow the requirements of the user manual for standard installation, use and daily maintenance.
    5)The energy storage system is ordered and shipped in the form of independent power modules and battery modules, and the quantity corresponds to the required system and equipment.
    6)Recommended charging method: Constant current charging of 50A to 57.6V.

Messages