Air conditioners and water pumps typically consume 2% to 4% of the system throughput. Liquid cooling maintains tighter control over cell temperature, which usually extends cycle life and delivers better performance in high-temperature regions, at the cost of higher initial investment and more maintenance points. Liquid cooling often pays for itself in hot areas, while air cooling is usually more cost-effective in mild climates.
Available kWh (specify depth of discharge, temperature, and end-of-warranty state) to avoid the most common comparison errors.
Warranty cycle count and end-of-life capacity guarantee: 6,000 cycles to 70% capacity ≠ 6,000 cycles to 80% capacity.

Round-trip efficiency: Measured on the AC side at the grid connection point. A 2-percentage-point difference translates to substantial real financial gains after thousands of cycles.
Scope of supply: PCS, transformers, switchgear, civil works, and installation — this is a common source of seemingly "cheap" quotes.
Party responsible for freight, customs duties, and warranty labor: A decisive clause for overseas projects.
EMS capabilities: Forecasting, multi-objective dispatch, and data export determine how much additional revenue you can generate.
Fire and safety certifications recognized by local authorities: Non-compliance may directly halt the project at the grid connection acceptance stage.
Expansion path: Whether a second unit can be paralleled later, leaving a fallback for selection mistakes.
Forecast PV output and load, rather than only performing passive response.
Execute multi-objective dispatch (self-consumption + demand capping + peak-valley arbitrage) with user-configurable priority levels.
Stay within warranty boundaries (depth of discharge, C-rate, temperature) instead of exceeding them for short-term performance indicators.
The payback period depends almost entirely on three local variables: peak-valley electricity price spread, basic electricity (demand) billing method, and the number of full cycles the site can run in a year. These three factors vary drastically across regions and electricity pricing mechanisms. Model using your own 12-month interval load data, do not rely on public average values. Meanwhile, require every supplier to provide the dispatch simulation behind their payback period calculation.